  Datasheet File OCR Text:
 125W Triple Output Switching Power Supply
Features :
R T- 1 2 5
series
Protections: Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 7)
RT-125A CH1 5V 12A
Note.6 2 ~ 15A Note.6 131W
RT-125B CH2 12V 5.5A 0.5 ~ 6A CH3 -5V 1A 0.1 ~ 1A CH1 5V 12A 2 ~ 15A 132W CH1: 4.75 ~ 5.5V 2.0% +8,-3% 0.5% 1.0% 1.0% 3.0% CH2 12V 5A 0.5 ~ 6A CH3 -12V 1A 0.1 ~ 1A
RT-125C CH1 5V 10A 2 ~ 15A 132.5W CH1: 4.75 ~ 5.5V 2.0% +8,-3% 0.5% 1.0% 1.0% 3.0% CH2 15V 4.5A 0.5 ~ 6A CH3 -15V 1A 0.1 ~ 1A
RT-125D CH1 5V 8A 2 ~ 15A 136W CH1: 4.75 ~ 5.5V 2.0% 5.0% 0.5% 1.0% 1.0% 3.0% CH2 24V 3A 0.4 ~ 4A CH3 12V 2A 0.1 ~ 2A
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 150mVp-p 120mVp-p CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +8,-3%
Note.4 Note.5
+6,-10% 1.0% 6.0%
6.0% 1.0% 6.0%
6.0% 1.0% 6.0%
6.0% 1.0% 6.0%
0.5% 1.0%
1.0% 3.0%
500ms, 20ms/230VAC 25ms/230VAC 47 ~ 63Hz 79%
1200ms, 30ms/115VAC at full load 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage) 81% 82%
30ms/115VAC at full load
88 ~ 132VAC / 176 ~ 264VAC selected by switch 80%
3A/115VAC 2A/230VAC COLD START 40A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY MTBF
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 209.3Khrs min. MIL-HDBK-217F (25 199*98*38mm (L*W*H) 0.7Kg; 20pcs/14Kg/0.8CUFT )
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RT-125-SPEC 2007-03-22
125W Triple Output Switching Power Supply
Mechanical Specification
197
R T- 1 2 5
Case No. 902A
series
Unit:mm
9
1
8.25
2 3 4
80 98 38
3.5
5 6 7 8
7
3.5
4-
M
3
4.5
57.5 199
120
6.5
190
18
9.5
9
22
157
Terminal Pin No. Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment NC DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1
Derating Curve
Static Characteristics
Ta=25
100
100 90
80
80 70
60
LOAD (%)
LOAD (%)
40
60 50 40
20
-25 -25
0 0
10
20
30
40
50
60
70 (VERTICAL) (HORIZONTAL)
88 176
95 190
100 200
115 230
120 240
28.5
3-M
3
18
3.5
85.5
7
132 264
AMBIENT TEMPERATURE ( )
3.5
INPUT VOLTAGE (VAC) 60Hz
File Name:RT-125-SPEC 2007-03-22


▲Up To Search▲   

 
Price & Availability of RT-125

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .